Over 150 California Auctions End Tomorrow 05/31 - Bid Now
Over 850 Total Lots Up For Auction at One Location - NJ Cleansweep 06/13

spacer
Listing 3592518
Listing 3592518

For Sale SMITHS MEDICAL Prizm PCS II 6101 Pump IV Infusion

  • Asking Price :$795.00 USD [convert]
  • Condition : Used - Excellent
  • Weight : 1.25 Lbs
  • Qty. Available : 1
  • In Stock : Yes
  • Date : May 27, 2024
  • Listing # : 3592518
cps-logo Get a CPS 2-Year Protection Plan starting at $5.99. Sold separately. Learn more
Advertisement

Item Description

Seller assumes all responsibility for this listing..

Listing: #3592518

  • Condition: Used - Excellent
  • Brand: SMITHS MEDICAL
  • Type: Pump IV Infusion
  • Model: Prizm PCS II 6101
  • MPN: PCSII-6101
  • Depth: 4 inches
  • Height: 10 inches
  • Width: 6 inches
  • Warranty: 6 Months

The Smiths Medical CADD Prizm PCS II 6101 (#PCSII-6101) is an ambulatory pump or drug delivery system that's been specially designed to perform patient controlled analgesia infusions. By doing so, this top-of-the-line pump provides measured drug therapy to patients in hospital or outpatient settings and it can be programmed to deliver medication at a constant rate or to allow the delivery of bolus dose at a specified time interval. It is indicated for intravenous, intra-arterial, subcutaneous, intraperitoneal, epidural space, or subarachnoid space infusion and is perfect for therapies that require a continuous rate of infusion, patient controlled demand doses, or both.

Warranty: 6 Months.

Note: The following error codes are used to indicate a problem.

  • 10102.
  • 20201.
  • Wrong Cassette.
  • High Pressure.
  • 10040.
  • 10038.
Smiths Medical CADD Prizm PCS II 6101 Features
  • Performs patient controlled analgesia infusions.
  • Ideally suited for hospital or outpatient settings.
  • Can be programmed to deliver medication at a constant rate and/or allow delivery of bolus dose at a specified time interval.
Smiths Medical CADD Prizm PCS II 6101 Specifications

General

  • Resolution: Medication Cassette Reservoir or CADD Administration Set, 0.050 ml per pump stroke nominal.
  • Size: 4.4 cm x 10.4 cm x 14.1 cm (1.7 in x 4.1 in x 5.6 in) excluding cassette or other accessories.
  • Weight: 568 g (20 oz) including 9 volt battery and empty 100 ml Medication Cassette Reservoir, excluding other accessories.
  • Pump Alarms: Low battery power, depleted battery power, external power source low, faulty, depleted, pump stopped, pump fault, low reservoir volume, high delivery pressure, air in line, air detector faulty or detached (only with the use of the optional air detector), air detector port cover detached, delivery too slow, key stuck, cassette detached or unlocked, print failure.
  • Bolus Volume at Occlusion Alarm Pressure:
    • 0.050 ml resolution administration sets/Medication Cassette Reservoirs: < 0.25 ml.
    • 0.100 ml resolution administration sets: < 2.0 ml.
  • Power Sources: 9 volt alkaline or lithium battery such as Duracell alkaline MN 1604 or Ultralife Lithium U9VL, CADD External Power Source (EPS) Power Pack recorder number 21-3801, AC Adapter.
  • System Operating Temperature: 2° C to 40° C (36° F to 104° F).
  • System Storage Temperature: -20° C to 60° C (-4° F to 140° F).
  • Power Pack Charging Temperature: 10° C to 35° C (50° F to 95° F).
  • System Delivery Accuracy: ± 6% (nominal).

PCA Delivery Mode Specifications

  • Reservoir Volume: 1 to 9999 or not in use, programmable in 1 ml increments, displayed in 0.1 ml increments.
  • Units: Milliliters (ml), milligrams (mg), micrograms (mcg).
  • Concentration:
    • Mg/ml: 0.1, 0.2, 0.3, 0.4, 0.5, 1, 2, 3, 4, 5, 10, 15, ...95, 100.
    • Mcg/ml: 1, 2, 3, 4, 5, 10, 15, ...95, 100, 200, 300, 400, 500.
  • Continuous Rate: 0 - 30 ml/hr (or the mg or mcg equivalent).
  • Demand Dose: 0 to 9.9 ml.
    • Delivery Rate (Continuous Rate + Demand Dose): 125 ml/hr nominal.
  • Demand Dose Lockout: 5 minutes to 24 hours in the following increments
    • 1 minute for values between 5 and 20 minutes.
    • 5 minutes between 20 minutes and 24 hours.
  • Max Doses per Hour: 1 - 12 doses in 1 dose increments (will also be limited by the Demand Dose Lockout value).
  • Demand Doses Given: 0 to 999.
  • Demand Dose Attempts: 0 to 999.
  • Given: 0 to 99999.99 in 0.01 unit increments.
  • Clinician Bolus: 0.1 ml to 20.00 ml (or mg or mcg equivalent).
    • Delivery Rate (Continuous Rate + Clinician Bolus): 125 ml/hr nominal.
  • High Pressure Alarm: 18 ± 9 psi.
  • Air Detector Alarm: Single bubble greater than 0.100 ml.

Options

  • AutoLock: Not in use, LL1, or LL2.
  • Time: 00:00 to 23:59.
  • Air Detector: Turned on or turned off.
  • Event Log: 0 - 500 events.
  • Extended History: Up to 48 hours in 1 hour increments.

Biomed Toolbox

  • PM (Preventive Maintenance) Reminder: 1 to 24 months in 1 month increments, Not in Use.
  • Custom Lock Level Code: 001 - 899 (excluding preset code) in increments of 1.
  • Date Format: US Standard (mm/dd/yy) or European Standard (dd/mm/yy).
  • Power Source Display: Always display or only low battery.
  • Air Detector Required:Required or not required.
Item Name: Infusion Pumps

Return Policy

30 Day Return Policy. Free Return. Return Policy: https://help.mfimedical.com/en-US/return-policy-204649
Tags: IV Infusion Pump
Seller Information
MFI Medical
Shop with confidence
Citi Capital Groupspacer
Send the Seller a message: