Over 100 Texas Auctions End Today - Bid Now
Over 650 Total Lots Up For Auction at Three Locations - TX 05/06, NJ 05/08, WA 05/09

spacer
Listing 4545470 Listing 4545470 Listing 4545470 Listing 4545470 Listing 4545470 Listing 4545470 Listing 4545470 Listing 4545470
Listing 4545470 Listing 4545470 Listing 4545470 Listing 4545470 Listing 4545470 Listing 4545470 Listing 4545470 Listing 4545470

For Sale MEDTRONIC 5348 SSI Temporary Pulse Generator with NEW 5433A patient cable Pacemaker

  • Original Price :$550.00 USD
  • Asking Price :$495.00 USD (10% Off) [convert]
  • Condition : Used - Good
  • Est. Shipping(US) : $20.00 USD
  • Qty. Available : 8
  • In Stock : Yes
  • Ships Within : 2 Days
  • Date : April 29, 2024
  • Listing # : 4545470
  • credit-card
  • credit-card
  • credit-card
  • credit-card
Advertisement

Item Description

Seller assumes all responsibility for this listing..

Listing: #4545470

  • Condition: Used - Good
  • Brand: MEDTRONIC
  • Type: Pacemaker
  • Model: 5348 SSI Temporary Pulse Generator with NEW 5433A patient cable
  • MPN: 5348
  • Power Supply Voltage: 9 VDC (common battery)
  • S/N: sample: PEP030899P, PEP015457P or PEP029347P
  • Warranty: 7 day inspection
FREE SHIPPING to the continental USA.

This is a package deal which includes a used apparently functional and undamaged 5348 external pulse generator / pacemaker and a new 5433A Atrial patient cable in its original seal Medtronic packaging. We have a few of these pulse generators and cables left in stock, all complete, apparently working and without damage. The controls are fully functional, the display clear and responsive and there are no cracks or other damage on the pacemaker's housings or keypads.

The device may be returned for a refund if it is found to be defective or damaged when inspected. Likewise with the cable, however the cable must be returned in sealed packaging with no signs or opening or use. The listed price is for the purchase of a 5348 pacemaker as pictured with one 5433A cable in a sealed package. We do not have any other accessories for this product. We do have 5388 dual chamber pacemakers in the same condition in stock. A copy of the manual for these products may be downloaded at no charge from online sources.

If you are replacing a damaged unit, we do have a couple of these missing their metal clips from the rear which are available for $25 less than the listed price. (please write before you buy in order to get this price). A picture of the rear of a couple of these incomplete functional units has been added (green background)

According to the manufacturer:

The Medtronic Model 5348 is a temporary, battery-powered, single chamber pacemaker designed primarily for temporary antibradycardia pacing therapy in asynchronous or demand (synchronous) modes. High-rate burst pacing therapy up to 800 min-1 (reciprocal minutes) (ppm [pulses per minute]), for tachyarrhythmias, is available in the asynchronous mode1.

The device is typically connected to temporary transvenous, epicardial or myocardial pacing leads, in a bipolar configuration using a patient cable (Medtronic Model 5433A or 5433V) or a surgical cable (Medtronic Model 5832 or 5832S).

The Medtronic model 5348 pacemaker is intended to be used in conjunction with a cardiac pacing lead system for temporary atrial or ventricular pacing in a clinical environment. The Model 5348 can be used where short-term demand (synchronous) or asynchronous pacing is indicated for therapeutic, prophylactic or diagnostic purposes. Specific indications for temporary cardiac pacing include, but are not limited to, the following:
* Sinus bradycardia;
* Sick Sinus Syndrome;
* Complete heart block;
* Bradycardia with congestive heart failure;
* Atrial and/or ventricular arrhythmias;
* Cardiac arrest;
* Temporary support, management, and evaluation of a patient prior to permanent pacemaker implantation;
* Support during permanent pacemaker replacement;
* Cardiac complications during invasive or surgical procedures;
* Temporary support of a patient following cardiac surgery;
* Acute myocardial infarction complicated by heart block; and
* High-rate burst pacing for the treatment of supraventricular tachyarrhythmias.

The Model 5348 can be used to determine sensing potentials of temporary and permanently implanted lead systems. When implanting a permanent pacemaker, however, Medtronic recommends the use of a Medtronic Pacing System Analyzer.

The Medtronic Model 5348 is designed to be reliable, simple to operate, and comfortable to hold. Safety features of the Model 5348 include:
* Self-tests;
* Low Battery indicator;
* Continuous operation during battery replacement (at 80 min-1 [ppm], 10 mA) for a minimum of 15 seconds;
* Reversible battery polarity;
* Protective covers over the controls and a rubber seal covering the heartwire receptacles;
* Safe “power-off” operation (Two buttons must be pressed simultaneously to turn the device off.);
* Cautionary label at the Rapid Atrial Pacing (RAP) controls;
* Detents (mechanical restrictions of dial movement) on the RATE and SENSITIVITY dials to highlight extremes or potentially hazardous settings;
* Safety cables (recessed pins);
* Runaway rate protection;
* Protection from defibrillation shock up to 360 watt-seconds;
* Electrostatic protection; and
* Minimized susceptibility to electromagnetic and magnetic interference.
* Modes: Synchronous (AAI/VVI) (demand) and asynchronous (AOO/VOO)
* Base level pacing rates: 30 - 180 min-1 (ppm) (continuously adjustable) ± 10%a
* Rapid atrial pacing rates:
80 - 380 min-1 (ppm)
(5 min-1 [ppm] increments) ± 10%
380 - 540 min-1 (ppm)
(10 min-1 [ppm]) increments) ±10%
540 - 800 min-1 (ppm)
(20 min-1 [ppm]) increments) ± 10%
* Output amplitude: 0.1-20 mA (cont. adjustable) ± 15% plus ± 0.1 mAa
* Pulse width: 1.8 ms ± 10%b
* Sensitivity: ASYNC., 0.5 to 20 mV (continuously adjustable) ± 25% or ± 0.30 mV (whichever is greater), including polarity disparitya,c
* Refractory: 250 ms ± 5%d
* Blanking: Pace: 125 ms (+ 50 ms; - 0 ms)d
* Sense: 75 ms (+ 50 ms; - 0 ms)d
* Rate limit: A crystal is used to set the pacing rate. If the crystal rate deviates from the appropriate value, the rate runaway protection circuit resets the device once. If the crystal rate remains incorrect, the rate runaway protection circuit turns the device off.
* Height: approximately 18.8 cm (7.4 inches)
* Width: approximately 6.1 cm (2.4 inches)
* Depth: approximately 4.1 cm (1.6 inches)
* Weight: approximately 283 g (10 oz.) (with battery)
* Operating temperature: 10°C to 43°C (50°F to 110°F)e
* Storage temperature: -40°C to 70°C (-40°F to 158°F) (without battery)
* Storage humidity: 90% maximum
* Battery type: Standard 9 V, Alkaline Type 6LR61 or Type 6F22E or equivalent

Please see our DOTmed webstore for other models of Medtronic pulse generators including the 5375 and 5388 (dual channel) models. We will consider offers on purchases of pacemakers without cables and cables without pacemakers as well as bulk purchases. We have been selling this particular model for quite a while and have no interest in clearing them out as they sell well. Please make offers with this in mind.

American buyers will pay only what they pay on purchase. No added taxes or fees will be required on delivery. Delivery normally takes one week.

This item is not for sale within Canada

Buyers from elsewhere are welcome to purchase this item. Shipping will be at cost

*************************************************
DISCLAIMER:

Regardless of the origin of the equipment, documentation provided or identification appearing upon the equipment, the equipment described and offered here is in no way certified for, recommended for, or offered for any specific use. The buyer is purchasing an item(s) which may have been used for medical purposes and may have the potential to again be used for this purpose, however, unless otherwise specified, at the time of sale the item is not considered to be bio-medically certified for use in any jurisdiction. The purchased item(s) is simply a device which operates in the limited manner described in the listing and/or electronic and mechanical components.

The purchaser agrees that the seller shall not be held responsible or liable for:

* any injuries or damages, whether incidental or consequential, associated in any way with the equipment;

* compliance with regulations on ownership or use of the purchased item within the jurisdiction in which the purchaser resides and/or uses the item.

The purchaser, by buying this equipment, indicates their acknowledgement of, and agreement to the terms of this disclaimer.

The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and other national/provincial/territorial/state and local regulatory agencies. If so, do not buy this item unless you are an authorized purchaser. If the item is subject to Health Canada or FDA regulation and it is to be used for regulated medical services in the USA, your payment for it indicates you are an authorized purchaser and will comply with these regulations. If you have questions about legal obligations regarding sales of medical devices, you should consult with the FDA or the regulatory authorities in the jurisdiction in which the item is to be used

Return Policy

7 Day Return Policy. Customer must pay the return shipping costs when returning a product. If you find the item is not as described in the ad it may be returned for a purchase price refund. Generally, all of our items have an inspection warranty which kicks in upon delivery for a period of 7 to 14 days. It is not an operational warranty as most items sold on DOTmed require biomedical certification before use. If you require additional coverage please contact us prior to purchase.