For Sale POCVODA PV-2000BV ICU/CCU

  • Asking Price :$580.00 USD [convert]
  • Condition : New
  • Qty. Available : 1
  • In Stock : Yes
  • Date : May 21, 2024
  • Listing # : 4308261
Advertisement

Item Description

Seller assumes all responsibility for this listing..

Listing: #4308261

  • Condition: New
  • Brand: POCVODA
  • Type: ICU/CCU
  • Model: PV-2000BV
  • MPN: PV-2000BV
  • Warranty: 12 MONTHS
Features:
1、Waterproof design appearance,low power consumption,without air fan and silence,use 13—20V output DC,battery working time is at least 4hours,recharge time is 2.5hours。Suitable for medical field rescue、ambulance、move and transit。
2、display mode of big font、trend review、ECG 7 lead,support one key operation,touchable screen is optional。Suitable for all working places,can used for neonate,child,adult,support mode of diagnose、monitor、operation。
3、13 type arrhythmic analysis,7-lead ECG waveform display in phase. 15 type drug calculation and titration table。
4、efficient resistance to interference of defibrillator and electrosurgical cautery,respiration can choose I\II,meet requirement of operation、ward。
5、use digital SpO2 technology,can test for 0.1% weak,high accuracy。
6、anti-ESU,anti-defibrillator,RA-LL impedance respiration,digital filtering。
7、double over-pressure NIBP protect,temperature drift。

Specifications:

1.ECG
Lead mode: 3-lead or 5-lead cable
3-lead:RA、LA、LL,lead way:I,II,III
5-lead:RA、LA、LL、RL、V,lead way:I,II,III,aVR,aVL,aVF,V
gain: 250,500,1000,2000
Heart rate range:adult:15 ~ 300bpm (pulse/min.) neonate/child:15 ~ 350 bpm(pulse/min.)
accuracy:±1% or ±1bpm,
resolution:1 bpm(pulse/min.)
sensitivity >200 uV(peak-to-peak value)
Input resistance >5(mge)
bandwidth:
Diagnostic mode:0.05~130Hz
Monitor mode:0.5~40Hz
Operation mode:1~20Hz
Common mode rejection ratio
Diagnostic mode:>90 dB
Monitor mode:>100 dB
Operation mode:>100 dB
The electrode polarization voltage range 300mV
Pacemaker pulse detection
Can test following:
range:±2 mV ~ ±700mV
width:0.1ms ~ 2ms
rise time:10us~100µs
Pacemaker pulse suppression
When turn on pacemaker pulse,can restrain following data, does not influence pulse rate calculation:
range:±2 mV ~ ±700mV
width:0.1ms ~ 2ms
rise time:10us ~ 100µs
Baseline recovery time after defibrillation< 3 seconds
Sign range 8 mV (peak-to-peak value)
Calibrating signal 1mV(peak-to-peak value),accuracy 5%
ST measurement
Measure range:-2.0mV ~ +2.0mV
Measure accuracy:in range of -0.8 mV~+0.8mV the tolerance is ±0.02mV or ±10% take bigger one。
Undefinition in other range。
2.Respiration
Way: RA-LL impedance and RA-LA impedance.
Range: 0.3~3Ω
Base impedance range 200~4000Ω
Band width 0.1~2.5Hz
Respiration rate
range adult:2~120BrPM child and neonate:2~150 BrPM
resolution:1 BrPM
accuracy:2 BrPM
Apnea alarm 10~40 seconds
3.NIBP
Technology:Oscillometric
Mode: manual/auto/STAT
Measurement inerval time under auto mode is 1,2,3,4,5,10,15,30,60,90,120,180,240,480 minutes.
Measurement time under STAT mode is 5 minutes.
Pulse rate range 40~240 bpm
Measurement range and accuracy
range
adult SIS 40~270mmHg
DIA 10~215mmHg
mean 20~235mmHg
child SIS 40~200mmHg
DIA 10~150mmHg
mean 20~165mmHg
neonate SIS 40~135mmHg
DIA 10~100mmHg
mean 20~110mmHg
Static pressure range 0~300mmHg
Static pressure accuracy 3mmHg
Blood pressure accuracy: maximum average error 5mmHg;largest standard deviation 8mmHg
Over-pressure protect
Adult mode 300 mmHg
Child mode 240 mmHg
Neonate mode 150 mmHg
4.SpO2

range 0~100%
resolution 1%
accuracy 70~100%:2;0%~69%:undefinition
Pulse rate
range 20~300bpm
resolution 1bpm
accuracy 3bpm
5.TEMP
Suitable temperature probe YSI,CYF
Channel number: 1 channel
range 0~50C resolution 0.1C accuracy 0.1C(do not include error of probe)

Standard configuration:
1. main unit(include battery) for animal 1pc
2.5-lead ECG cable with clip 1pc
3.TEMP rectal probe 1pc
4.Animal NIBP cuff 1pc
5.NIBP tube 1pc
6.Animal SpO2 sensor 1pc
7.power cord 1pc


Optional functions
1、 Touchable screen
2、 CO2