Over 150 Total Lots Up For Auction at One Location - CA 05/31

spacer
Listing 4861096 Listing 4861096
Listing 4861096 Listing 4861096 Listing 4861096

For Sale BD BIOSCIENCES FACSCanto II Flow Cytometer

  • Asking Price :$23,995.00 USD [convert]
  • Condition : Used - Good
  • Qty. Available : 1
  • In Stock : Yes
  • Date : May 19, 2024
  • Listing # : 4861096
Advertisement

Item Description

Seller assumes all responsibility for this listing..

Listing: #4861096

  • Condition: Used - Good
  • Brand: BD BIOSCIENCES
  • Type: Flow Cytometer
  • Model: FACSCanto II
  • MPN: 48792
  • Warranty: 60 Days Warranty
Here is a BD FACSCanto II Flow Cytometer (3)Lasers/(8)Colors/(10)Detectors with HT Sampler

Predecessor to:
Current model

Condition:
This BD FACSCanto II Flow Cytometer system is in good working condition.

Please see the exact video and photos below.

Testing we performed:
The BD FACSCanto II Flow Cytometer system passed all tests and was found to be fully functional:
Power on: PASSED
Communication with FACSDiva software: PASSED
Ran fluidics priming and startup sequences: PASSED
Ran several cleaning cycles (long clean, flow cell clean, etc.): PASSED
Tested functionality of HTS: PASSED
Test Run with 8-Peak Rainbow Beads: PASSED
Performed baseline test with CS&T beads: (Beads on Backorder) PASSED
Performed performance check with CS&T beads: (Beads on Backorder) PASSED

System consists of:
BD FACSCanto II Flow Cytometer
BD High-Throughput Sampler (HTS)
BD FACSCanto Fluidics Supply Cart
BD FACSCanto Fluidics Supply Cart Harness
(4) Fluidics Level Sensors (Sheath, Waste, Clean, Shutdown)
Waste Container
Desktop Computer equipped with FACSDiva Software
FACSDiva Software License Dongle
Computer Monitor, Keyboard, and Mouse
Communication Cables and Display Cables

Standard Power Cables


Configuration and Setup:
Optics:
(3) Lasers: 488nm Blue / 633nm Red / Violet 405nm
(8) Colors simultaneously
(10) Detector Channels

- FSC Detector: Photodiode with 488/10 BP; FSC Resolution: 1.0 um
- SSC Detector: PMT with 488/10 BP; SSC Resolution: 0.5 um

Fluorescence Detector Design: Reflective optics with a single transmission filter in front of each PMT
Fluorescence Detectors: 8 PMTs in 4-2-2 standard configuration
- 488nm blue laser: Channel A(780/60, 735LP) Channel B(>670LP,655LP) Channel D(585/42,556LP) Channel E(530/30, 502LP)
- 633nm red laser: Channel A(780/60, 735LP), Channel C (660/20)
- 405nm violet laser: Channel A(510/50, 502LP), Channel B (450/50)
Common Fluorochromes Detected: PE-Cy7, PerCP-Cy5.5, PE, FITC, APC-Cy7, APC, AmCyan, and Pacific Blue (Ask Us if compatible with your planned Fluorochromes)

Fluorescence Threshold Sensitivities: FITC <100 MESF; PE <50 MESF
Sheath Consumption: 1.10 L/h normal operation; <1 mL/h standby
Carryover: =0.1%
Sample Injection: Direct into flow cell
Max Particle Size: 50 um
Sample Flow Rate, Min: 10 uL/min
Sample Flow Rate, Max: 120 uL/min
Sample Acquisition Rate: 10,000 events/second,
Sample Handling: Manual Tube Loading, High-Throughput Sampler (96-well U-bottom, V-bottom, flat bottom, 364-well flat bottom microplates)
Size (D x W x H) Cytometer: 24 x 36 x 25 in. (61 x 91 x 64 cm)
Weight Cytometer: 320 lb (145 kg)

Video Description:
The video below gives an overview of the BD FACSCanto II Flow Cytometer system and also demonstrates its functionality.

TO VIEW ADDITIONAL PHOTOS, VIDEOS AND VERY DETAILED INFORMATION SUCH AS TEST STEPS PERFORMED, CONFIGURATION, ETC., PLEASE VISIT OUR WEB SITE. TO GET THERE PLEASE CLICK ON “WEBSTORE”; TO YOUR RIGHT AND YOU WILL SEE LINK TO OUR SITE IN THE MIDDLE OF THE SCREEN. THEN USE LAST 5 DIGITS OF MPN NUMBER IN THE SEARCH FIELD TO LOCATE YOUR ITEM.

DO NOT HESITATE TO CALL US OR EMAIL US WITH ANY QUESTIONS YOU MIGHT HAVE.

ALL OF OUR ITEMS ARE AVAILABLE FOR INSPECTION AT OUR FACILITY.

Return Policy

Items are sold as-is with no returns or refunds available unless explicitly stated.
Seller Information
Boston Industries, Inc.
Shop with confidence
Citi Capital Groupspacer
Send the Seller a message: