Over 950 Cleansweep Auctions End Tomorrow 05/02 - Bid Now
Over 800 Total Lots Up For Auction at Four Locations - TX 05/03, TX 05/06, NJ 05/08, WA 05/09

spacer
Listing 4876482 Listing 4876482 Listing 4876482 Listing 4876482 Listing 4876482 Listing 4876482
Listing 4876482 Listing 4876482 Listing 4876482 Listing 4876482 Listing 4876482 Listing 4876482

For Sale TOSHIBA Aquilion One 320 CT Scanner

  • Asking Price :£75,000.00 GBP [convert]
  • Condition : Used - Good
  • Qty. Available : 1
  • In Stock : Yes
  • Ships Within : 3 Days
  • Date : April 27, 2024
  • Listing # : 4876482
  • credit-card
  • credit-card
  • credit-card
  • credit-card
Advertisement

Item Description

Seller assumes all responsibility for this listing..

Listing: #4876482

  • Condition: Used - Good
  • Brand: TOSHIBA
  • Type: CT Scanner
  • Model: Aquilion One 320
  • MPN: UK0003-2cc10z2266
  • Gantry Count : 55919036
UK0003-This item is available at our UK warehouse thornlibank Glasgow G468JN .... the contact person.
Seems to be in a good functional & cosmetic condition; showing mild to moderate signs of wear from use, As item is removed from working environment, therefore any damage is cosmetic only and does not impede functionality. Due to lack of accessories only Power-on and general function/s test was performed & found OK, therefore selling “As is", For further details & condition see pictures. Summary of specs. is mentioned also:
System Information:
Manufacturer and
model: Toshiba Aquilian One CT Scanner
System model no:TSX-301A/2C
System serial no:2CC10Z2266
System YOM:2010
Number of slices:3631352
Air or water cooling?:Tube cooled by Heat Exchanger/Coolant
Gantry & Detector Information:
Gantry YOM: 2010
Gantry model no.:CGGT-024A/1A
Gantry serial no.:1AB10Z2284
Gantry count:55919036
rotations
Detector model no;320 Row Detector
Detector serial no:
Detector YOM: 2010
Tube Information:
Tube Type:MCS-7088A
Tube Housing model:8-608H
Tube Housing serial
no.:H47343
Tube Insert model no.:MCS-7088A
Tube Insert serial no.:47343-1v
Tube YOM:2021
Workstation model no:CKCN-015A/2A
Workstation serial no. 2AA10Z2026
Workstation software version:V6.0SP0606E Base Version : 10.0SP0001
Workstation software options: Scan Console:
CARDIAC, CARDIACPATCH,CARDIACRECON,DE SCAN,DOUBL LfCE,D PRT BW,
D_PRT_COLOR,EHCP SCP,EHCP_SCU,FLUOROSCOPE,MULTIVIEW,MWM SCU,ORBITS NC, OVER64HEL,PRINT SCU,REALEC,REAL PREP, REAL_VtEW,S N320ROW,STRG SCU,VHP, WINPRT
Display Console:
ALATO 3DVIEWER,ALATO MULTISLICECT,ALATO STANDARD,DCM CDR,DE GOUT, DE MEAS TOOL,DOUBLESLICE,D PRT BW,D PRT COLOR,EHCT SCP,MULTIVIEW,
PRINT SCU,QR SCP,QR SCU,REGISTTOOL,SCAN320ROW,TIFF,TSB DVD,VOL BODYPERF,WINPRT


You should have this item completely checked out prior to use in conjunction with patient care.
We will stand by our equipment but will not take any responsibility for its use on patient.
Refer to disclaimer below.
DISCLAIMER;
We are not selling nor providing or assisting in any licensing, operations, registration, replacement, services, or warranty. This equipment is being sold “AS-IS” with 30 days return(If explicitly Mentioned). Regardless of the origin of the equipment, documentation provided or identification appearing upon the equipment, the equipment described and offered here is in no way certified for, recommended for, or offered for any specific use. The purchaser agrees that seller is not liable for any injuries or damages of any kind associated in any way with this equipment. Purchaser agrees to indemnify and hold harmless seller and seller's officers, directors, employees, agents, and shareholders against any and all claims, liabilities, obligations, demands, cost and expenses of every kind and nature, including but not limited to attorney's fees and litigation expenses, from or related to the equipment and any use thereof. Finally, please be aware that by buying this item you are acknowledging and agreeing with the above mentioned
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item. Purchase of some medical devices that may be labeled “Caution” or “RX only” requires that purchaser is a licensed physician or work under the direct supervision of a licensed physician. Ensuring this supervision is the purchasers' responsibility.
By buying this item, the purchaser acknowledges/declares that He/She/They are authorized and properly trained to use/Operate.
SHIPPING.
We are not shipping to international destinations out of UK. Only local standard freight services are used, therefore packing, local warehouse pickup and Shipment fright charges are not included in the item price. These charges are the buyer's responsibility. Please check carefully in our lists to determine what these additional costs will be prior to bidding or buying.
• Please clearly specify Commercial or Residential address. Also clearly mention about unloading facilities, like fork lifter/truck bays etc.

Return Policy

Items are sold as-is with no returns or refunds available unless explicitly stated.
Seller Information
APPEX MEDICAL LLC
profile image
Shop with confidence
Citi Capital Groupspacer
Send the Seller a message: