For Sale WATERS Acquity UPLC-PDA-FLR-2 Chromatograph

  • Asking Price :$13,995.00 USD [convert]
  • Condition : Used - Good
  • Qty. Available : 1
  • In Stock : Yes
  • Date : May 14, 2024
  • Listing # : 4895696
Advertisement

Item Description

Seller assumes all responsibility for this listing..

Listing: #4895696

  • Condition: Used - Good
  • Brand: WATERS
  • Type: Chromatograph
  • Model: Acquity UPLC-PDA-FLR-2
  • MPN: 51846
  • Warranty: 60 Days Warranty
For Sale Waters Acquity UPLC Liquid Chromatography System with PDA and FLR Detectors

Pre-owned instrument

• Fully Functional
• In Stock
• Good cosmetic condition
• Warranty

Here is what you will receive:
• Binary Solvent Manager (model #186015001)
• Sample Manager (model #186015006)
• Column Heater (model #186015010)
• Solvents Tray
• PDA Detector (model #186015032) w/ Analytical Flow Cell 500nL
• FLR Detector (model #186015029) w/ Standard Flow Cell
• Inter-communication cables
• Standard power cords.

Please Note: Computer and Empower 3 software license will need to be purchased from Waters. They are not included and are only used for testing.

Waters Acquity UPLC Liquid Chromatography System with PDA and FLR Detectors Configuration:
Acquity UPLC Binary Solvent Manager:
• Number of solvents: up to four in any combination of two: A1 or A2 and Bl or B2
• Solvent storage: solvents tray accommodates up to four chromatographic solvents, two Sample Manager wash solvents and one Binary Solvent Manager seal wash solvent
• Solvent conditioning: vacuum degassing (six-channel): one channel per solvent, and two channels for Sample Manager wash solvents
• Operating flow rate range: 0.010 to 2.000 mL/min, in 0.001 mL increments
• Compressibility compensation: automatic and continuous
• Effective system delay volume: < 120 uL, independent of system backpressure (with standard 50-uL mixer installed)
• Plunger seal wash: integral, active, programmable
• Gradient profiles: 11 gradient curves including linear, step (2), concave (4), and convex (4)
• Wet prime: automatic
• Maximum operating pressure: 15,000 psi up to 1 mL/min, 9,000 psi up to 2 mL/min per pump, not more than 15,000 psi total

Acquity UPLC Sample Manager:
• Number of plates: two plates of 96 and 384 microtiter plates / 48 position 2.00-mL vial plates / 48 position 0.65-mL micro-centrifuge tube plates /24 position 1.50-mL micro-centrifuge tube plates
• Maximum sample capacity: 768 in two 384-well plates
• Number of sample injections: 1 to 99 injections per sample
• Injection volume range: 0.1 to 50.0 uL, in 0.1 uL increments, partial or full loop mode
• Sample delivery precision (full loop injection mode): < 0.3% RSD, full loop, standard 10-uL loop (default wash/purge conditions)
• Sample temperature control:4DegC - 40DegC, settable in 0.1 DegC increments (at an ambient temperature of 25DegC)
• Injection cycle time: < 15 sec between multipe injections with "load ahead" enabled; 30 sec with single weak wash, 10-pL loop, pressure assist mode
• Minimum sample required: 5 uL residual, using maximum recovery 2-mL vials (zero offset)
• Wash solvents: Two degassed: strong solvent and weak wash solvent, programmable to suit application
• Sample carryover: < 0.005% or < 2.000 nL

Acquity UPLC Column Heater:
• Column temperature control: 5DegC above ambient to 90DegC settable in 0.1 DegC increments
• Column tracking: eCord Technology column information management tracks and archives usage history
• Compartment temperature measurement accuracy: +/-1DegC
• Compartment heating rate: Less than 15 min., 5DegC above ambient to 40Degc

Acquity UPLC PDA Detector:
• Wavelength range: 190 to 500 nm
• Wavelength accuracy: ±1 nm
• Linearity range: deviation at 2.0 AU ≤5%
• Optical resolution: 1.2 nm
• Digital resolution: 0.6 nm/pixel to 500 nm
• Sampling rate: up to 80 points/s
• Light source: deuterium lamp
• Flow cell design (analytical): light-guiding UPLC intelligent technology flow cell
• Flow cell volume: 500 nL
• Path length: 10 mm
• Pressure limit: 1000 psi (all flow cells)

Acquity UPLC FLR Detector:
• Wavelength range: Ex.:200 to 890 nm; Em.: 210 to 900 nm
• Wavelength accuracy: ±3 nm
• Bandwidth: 20 nm
• Wavelength repeatability: ±0.25 nm
• Sensitivity: S/N >1000 (Raman spectrum of H2O)
• Measurement range: 0.001 to 10,000 EU
• Data acquisition: uUp to 80 Hz
• Flow cell design: axially illuminated
• Cell volume: <2 uL
• Pressure limit: 500 psi, for standard flow cell

Customization/Options:
Other detectors and flow cell options might be available. Please inquire with our sales team.

Testing performed by our in-house service team:
• We inspect the Waters Acquity UPLC Liquid Chromatography System.
• We check the seamless communication with the Empower software.
Binary solvent manager:
• We carefully evaluate the system's startup process for proper functionality.
• We check the seamless communication with the Empower software.
• We thoroughly assess the stability and consistency of solvent delivery.
• We verify accuracy of flow rates.
• We comprehensively evaluate the system's performance in creating and running gradient tests.
• The functionality of the pressure limiter undergoes testing for optimal safety and performance.
Sample manager:
• We conduct comprehensive checks to ensure the proper initialization of the sample manager.
• We carefully evaluate the accuracy of the sample cooler set temperature for consistency and precision.
• We test the function of the sample area and plate stage.
• We verify the reproducibility of sample handling processes.
Column heater:
• We carry out detailed checks to ensure the correct and stable initialization of the column heater.
• We run tests to verify the accuracy and stability of the column oven temperature.
• We stress test the column heater through the temperature range ensuring reliable operation.
PDA Detector:
• We perform extensive checks to evaluate the proper initialization of the PDA detector.
• We monitor the remaining lamp life to ensure optimal performance.
• We run tests to verify accurate and reliable detection capabilities.
FLR detector:
• We monitor the remaining life of the Xe lamp to ensure proper functionality.
• We run tests ensure high sensitivity and accurate detection of fluorescence signals.

Instrument Overview:
• The Waters Acquity UPLC Liquid Chromatography System is a high-performance instrument used for separating and analyzing compounds.
• It features a low-dispersion binary solvent manager for precise and accurate solvent delivery.
• The System includes a sample manager with temperature control for consistent sample handling.
• It also boasts a highly sensitive optical detection system for reliable analyses.
• With its robust design, it offers high efficiency and throughput for various analytical applications.
• The Waters Acquity UPLC System provides exceptional resolution and sensitivity for demanding chromatographic separations.

Instrument Application:
The Waters Acquity UPLC Liquid Chromatography System is commonly used in various applications including:
• pharmaceutical analysis
• environmental testing
• food and beverage analysis
• clinical research
• metabolite identification
• natural product analysis
Its high-performance capabilities make it well-suited for a wide range of analytical tasks in research and industry.

The key features of the Waters Acquity UPLC Liquid Chromatography System:
• High-performance liquid chromatography System
• Low-dispersion binary solvent manager
• Sample manager with temperature control
• Highly sensitive optical detection system
• Robust design for high efficiency
• Exceptional resolution and sensitivity

Additional technical info:
PDA Detector Flow cell options: (Please check to see what we have in stock if your needs differ from the advertised configuration.)
• Analytical - 500 nL, 10 mm path length
• High sensitivity - 2400 nL, 25 mm path length
• High throughput - 135 nL, 3 mm path length
• Stainless-steel - 1500 nL, 5 mm path length
• Titanium - 1500 nL, 5 mm path length
• Low dispersion analytical - 500 nL, 10 mm path length
• Low dispersion microbore - 250 nL, 10 mm path length
• Microscale - 100 nL, 10 mm path length

Why should you buy from us?

Our Advantage
• We have experience servicing and repairing these instruments.
• This instrument goes through all the described service steps before shipping.
• We offer detailed photos and videos of the instruments you buy.
• We are an approved pre-owned equipment vendor to many large US, Canadian, and EU Universities.
• We are an approved pre-owned equipment vendor to many Fortune 500 US and International Biopharma companies.
• Many upgrade and repair parts are in stock.
• Remote installation and instrument operation training are available.
• On-site installation may be available in the Boston Area (New England area)
• US or International shipping is no problem (see the shipping tab on how we pack and feel at ease)

Our Guarantee
• Warranty
• Smooth process from the initial quote to order fulfillment.
• Customer references are available.

*ME* Medium Crate
450#

PLEASE NOTE THAT THE QUESTIONS BELOW ARE ANSWERED IN MORE THOROUGH DETAIL ON OUR WEBSITE

Q: Can I view this instrument in person at your facility or do a live Zoom demo before it is shipped to me?
A: We can accommodate both in-person or Zoom demos.

Q: What about the warranty?
A: The instrument comes fully warranted for both parts and labor.

Q: Do you offer installation, service, etc?
A: We offer remote installation and training packages to familiarize you with this instrument.

Q: What should I watch out for when buying a used/pre-owned instrument from another lab?
A: Ensure that the instrument is in good working condition with no damage or wear that could affect its performance. Ask for details about testing steps performed, video demo, and test screenshots.

Q: Do you have more than one of these instruments on hand?
A: We generally carry multiple instruments on hand, along with a variety of spare parts.

Q: This procurement is for a University or College. Are purchase orders with NET terms accepted?
A: We accept purchase orders from all major US and Canadian universities.

Q: How fast will you ship?
A: We can ship within a few days to two weeks. Shipping time depends on the current demand for our instruments. Members of our sales team will be able to offer current delivery estimates.

Q: Will my instrument be insured during shipping?
A: Absolutely! We insure all our shipments as long as we are the shipper. If a customer ships on their account, they handle insurance.

Q: How do you pack? Have you previously packed and shipped the fragile laboratory instruments?
A: We have extensive experience shipping high-end and complex laboratory instruments in the US and Internationally.

Q: Do you ship Internationally?
A: Yes! We have shipped to multiple continents and over 30 countries.

Q: How much will I save buying it pre-owned, and is it worth it?
A: When compared to buying a new instrument, you will save 60% or more and have plenty of funds left over for an additional instrument or two.

TO VIEW ADDITIONAL PHOTOS, VIDEOS AND VERY DETAILED INFORMATION SUCH AS TEST STEPS PERFORMED, CONFIGURATION, ETC., PLEASE VISIT OUR WEB SITE. TO GET THERE PLEASE CLICK ON “WEBSTORE”; TO YOUR RIGHT AND YOU WILL SEE LINK TO OUR SITE IN THE MIDDLE OF THE SCREEN. THEN USE LAST 5 DIGITS OF MPN NUMBER IN THE SEARCH FIELD TO LOCATE YOUR ITEM.

DO NOT HESITATE TO CALL US OR EMAIL US WITH ANY QUESTIONS YOU MIGHT HAVE.

ALL OF OUR ITEMS ARE AVAILABLE FOR INSPECTION AT OUR FACILITY.

Return Policy

Items are sold as-is with no returns or refunds available unless explicitly stated.
Seller Information
Boston Industries, Inc.
Shop with confidence
Citi Capital Groupspacer
Send the Seller a message: